If a relevant element is absent from the configuration, this is auto-configured on non-Windows platforms, with default settings as noted below.
Attributes
Name | Type | Default | Description |
---|---|---|---|
address | local pathname | shibd.sock | Pathname to use for the Unix domain socket. Both the web server and shibd daemon processes need to be able to read and write to this path. |
stackSize
Can be set via the SHIBSP_LISTENER_ADDRESS environment variable. | |||
stackSize | size in kilobytes | 0 | If non-zero, sets the stack size of daemon worker threads in kilobytes. Zero results in the default OS-supplied size being used, which can be surprisingly large. |
clientAddress | local pathname | If set, this overrides |
address
attribute the address attribute for the "in-process" half of the system (web server modules). |
Child Elements
None
Example
Equivalent to Unix Default
Code Block | ||||
---|---|---|---|---|
| ||||
<UnixListener address="shibd.sock"/> |