InitialTesting

You can test to ensure that the SP is running properly and the surrounding environment is correct by accessing

https://localhost/Shibboleth.sso/Status 

from the actual web server machine itself. You MUST use "localhost" as the hostname or it WILL NOT WORK by default. If this test is successful, then the software is ready for further configuration.

You can also access the Status handler from other clients or using a non-localhost name, but only if you change the acl parameter in the configuration to permit your client address or remove it entirely to open up access to anybody. The ACL is present by default because the Status handler can return some arguably sensitive information about your configuration.

Now you can progress to the GettingStarted material. Once you've actually configured the SP with its own settings and metadata from at least one IdP, in order to check that the SP is "working":

  1. Protect a directory by requiring a Shibboleth session. Often, this is already done by default for the location "/secure".

  2. Next, you typically place a script inside the protected directory that dumps the web server environment. With PHP for example you could in the easiest case just place a script there with the following:

    <?php print_r($_SERVER) ?>

    For an IIS deployment, an example ASP.NET script:

    <% @ Page Language="C#" %> <% Response.Write("<h3>Server Variables</h3>"); foreach (string var in Request.ServerVariables) { Response.Write(var + " = " + Request[var] + "<br>"); } %>
  3. Make sure that the Shibboleth-supplied variables are present. If there is a non-empty variable called Shib-Application-ID, you successfully authenticated and have a valid session. However, you also should check if there are other non-empty Shibboleth variables defined in the attribute-map.xml file. If there are no variables like mail or givenName or surname, the IdP probably releaseed no attributes. In either case, have a look at the shibd.log and transaction.log files.